nlscan.com
Page 30
General ProgrammingGeneral Programming
Tools
Code Programming ON
Code Programming OFF
Reading Mode
Interval Mode
After programming, the engine will start interval scan without trigger. The interval
between two scans is fixed whether the scan is successful or not. The value of interval
could be programmed by user and the default value is 1s.
Interval Mode
【Pro CMD:99900112】
Interval Length
【Pro CMD:99900151】
Interval takes 500ms as a unit and could be classed in fifteen levels:0-15.For instance, interval could be
programmed to 5000ms:
Read“Code Programming ON” 1、
Read“ 2、 Interval Length”
Read numbers “1”“0” 3、
Read“ 4、 Code Programming OFF”
Reading a barcode time length
【Pro CMD:99900150】